| Options | |
| Option Code | Description |
| -LF | Limits maximum frequency to 500Hz -- 2253 i/iX only |
| -FC | Modifies output frequency control to ± 0.25% |
| -LKM | Clock/Lock Master |
| -LKS | Clock/Lock Auxiliary |
| -MODE | Allows all three amplifier outputs to be combined on phase A output terminal. No external switching or reconnection to the load is required (2253 i/iX only). |
| -RMS | Rackmount Slides |
| -RPF | Remote programming frequency (0-10 V DC). |
| -RPV | Remote programming voltage (0-10 V DC). |
| -WHM | Watt-hour measurement. |
| Controller Options | |
| Option Code | Description |
| -ABL | ABLE Command (Emulates Elgar SL - PIP 9012 Functions) |
| -EXE | External Sync Input. (Excludes LKS & RPF) |
| -LAN | LXI Ethernet LAN Inter face (RJ45 Connector) (iX Only) |
| Avionics Test Routine Options | |
| Option Code | Description |
| -ABD | Airbus Directive 0100.1.8 tests. [AC only]. Requires -ADV and use of Windows PC and included FCS Series II Instrument Control software. |
| -AMD | Airbus AMD24C Tests. Revision C. |
| -A350 | Airbus Test Software |
| -AIRB | Airbus ABD0100.1.8, AMD 24 and A350 combination test software suite |
| -B787 | Boeing 787B3-0147 Tests. |
| -704 | Mil-Std 704 rev D and E test firmware. [AC only, Refer to -704 option data sheet for detaiIs] |
| -704F | Mil Std 704 test firmware. Revisions A-F. |
| -160 | RTCA/DO-160D, Change 2, EuroCAE-14D and Airbus test firmware [Section 16, AC only. Refer to -160 option data sheet for detaiIs] |
| * Note Reference the Avionics Test User Manual P/N 4994-971 for a complete listing of performance capabilities. | |
| Feature Comparison | ||
| Controller | i | iX |
| AC mode | x | x |
| DC mode | x | x |
| AC+DC mode | - | x |
| ansient programming | x | x |
| Arbitrary waveforms | - | x |
| Measurements | x | x |
| Harmonic measurements | - | x |
| Waveform acquisition | - | x |
| Programmable Impedance | - | x |
| IEEE / RS232 | x | x |